Perkins Series Diesel Engine

For 75 years Perkins has always taken the lead in the design and manufacture of high-performance diesel engines in the field. The continuous development programme of Perkins offers one of the most advanced and comprehensive ranges of purpose-built diesel and gas engines available today. Meanwhile, it commits to providing the optimum power solutions for diesel engines.

1. 400 Series 11.2 to 39.3 kVA
a. 1.1 to 2.2 litre
b. In-line 3 and 4 cylinders
c. Naturally aspirated
The 400 series Perkins diesel engine, a significant evolution of the compact engine family, offers superior performance, with low emissions and low operating costs, all of which in a small efficient package.

2. 1100 Series 30 to 228 kVA
a. 3.3, 4.4 and 6.6 litre
b. In-line 3, 4 and 6 cylinder
c. Naturally aspirated
d. Turbocharged
e. Turbocharged and charge-cooled
1100 Series is a multigenerational product designed to provide an optimum range of power solutions for both areas with discharge limits or with no discharge limits.

3. 1000 Series 93 to 165 kVA
a. 6.0 litre
b. In-line 6 cylinders
c. Turbocharged
d. Turbocharged charge-cooled
Perkins advanced combustion technology makes the Perkins series diesel engine highly productive and fuel efficient. In addition, class leadership on the SAE maintainability index – a widely accepted means of comparing the serviceability of engines – and service intervals of up to 500 hours further minimizes operating costs of the diesel engines.

4. 1300 Series 189 to 275 kVA
a. 8.7 litre
b. In-line 6 cylinders
c. Turbocharged and charge-cooled
The 1300 series range features fully authorized electronic engines coupled with hydraulically actuated electronic controlled unit injectors, with clean, strong power, low noise and high fuel efficiency. This range of Perkins series diesel engines also boast proven reliability, remarkable design, and are fitted with low-cost roller cam and wet liners.

5. 2200 Series 350 to 500 kVA
a. 13 litre
b. In-line 6 cylinder
c. Turbocharged and charge-cooled
Developed on the basis of a proven industrial engine, this 13 litre turbocharged and charge cooled unit provides economic and reliable power at key modes in the industry. All the Perkins series diesel engines in this family meet the requirements of EPA/EC Stage 2 emission standards and are capable of meeting 1⁄2 TA Luft (1986) NOx levels.

6. 2500 Series 455 to 687 kVA
a. 15 litre
b. In-line 6 cylinder
c. Turbocharged and charge-cooled
The 2500 series builds on the strengths of the already very successful 2000 series family. This range of Perkins series diesel engines features exceptional power-to-weight ratio, resulting in exceptional fuel consumption. This engine offers power solutions to both emissions controlled and non-controlled areas.

7. 2800 Series 591 to 750 kVA
a. 18 litre
b. In-line 6 cylinders
c. Turbocharged and charge-cooled
A well proven family of 6 cylinder in-line engines is designed with particular focus on the standby sector. Developed from a proven heavy-duty industrial base, the 2800 Series Perkins diesel engines offer superior performance and reliability in economic operation with low exhaust emissions.

8. 4000 Series 585 to 2500 kVA
a. 23 to 61 litre
b. In-line 6 and 8 cylinders
c. Vee 12 and 16 cylinders
d. Turbocharged and charge-cooled
A unique piston and cylinder design, incorporating an individually operated unit fuel injector, gives the Perkins 4000 series diesel engines ultra-low fuel consumption and emissions. The gas powered engines available in this range received the Queen Award for Environmental Achievement.

The delicate design and reliable performance of the Perkins series diesel engine have won Perkins a vast client base. What's more, with increasing development of its agency service and distribution network, Perkins has grown into a top ranking supplier of 4-2000 kW (5 - 2600 hp) diesel and gas engines. Ranging from 5 to over 2,600 hp, the Perkins series diesel engines are widely adopted by a large number of equipment manufacturers in the construction, power generation, materials handling, agricultural and general industrial markets.

Technical parameters
Genset Power Selector Chart
50HZ Net Engine Output Typical Generator Efficiency Typical Power Factor Typical Generating Set Output 1500/1800 rev/min switchable
Model Baseload kWm Prime kWm Standby kWm % Baseload Prime Standby
kWe Kva kWe kVA kWe kVA
3000 rev/min (8.3 kVA to 36.4 kVA)
402D-05G * 7.7 8.5 86 0.8 * * 6.6 8.3 7.3 9.1
403D-07G * 11.5 12 12.6 0.8 * * 9.9 12.3 10.8 13.5
403D-11G * 16.5 18.1 18.1 0.8 * * 14.2 17.7 15.6 19.5
403D-15G * 20.2 22.2 22.2 0.8 * * 17.6 21.9 19.3 24.1
404D-22G * 29.7 32.7 32.7 0.8 * * 26.5 33.1 29.1 36.4
1500 rev/min (9 kVA to 2500 kVA)
403D-11G * 8.4 9.2 86 0.8 * * 7.2 9 7.9 9.9
403D-15G * 12 13.2 87 0.8 * * 10.4 13 11.4 14.3
404D-22TG * 18.4 20.3 88 0.8 * * 16.2 20.3 17.8 22.3
1103A-33G * 24.3 26.7 90 0.8 * * 21.8 27.3 24 30
1103A-33TG1 * 27.7 30.4 87 0.8 * * 24 30 26.4 33
1103A-33TG1 * 41.3 45.6 87 0.8 * * 36 45 39.7 49.6
1103A-33TG2 * 53.8 59.3 89 0.8 * * 48 60 52.8 66
1104A-44TG1 * 58.4 64.3 89 0.8 * * 52 65 57.2 71.5
1104A-44TG2 * 71.9 79.1 89 0.8 * * 64 80 70.4 88
1104C-44TAG2 * 90.1 99.5 90 0.8 * * 81.4 101.4 89.6 111.9
1006TG1A * 83 91.5 90 0.8 * * 74.5 93 82.5 103
1006TG2A * 91 100 90 0.8 * * 82 102.5 90 112.5
1006TAG * 121 133.5 90 0.8 * * 109 136 120 150
1006TAG2 * 129.3 143 93 0.8 * * 120 150 132 165
1106C-E66TAG4 * 158.4 175.5 93 0.8 * * 147.3 184.1 163.2 204
1306C-E87TAG3 164 180 199 92 0.8 151 189 166 208 183 229
1306C-E87TAG4 179 198 217 92 0.8 165 205 182 228 200 250
1306C-E87TAG5 185 204 224 92 0.8 170 213 188 235 206 258
1306C-E87TAG6 198 217 239 92 0.8 182 228 200 250 220 275
2206A-E13TAG2 * 305 349 92 0.8 * * 280 350 320 400
2206A-E13TAG3 * 349 392 92 0.8 * * 320 400 360 450
2506A-E15TAG1 * 396 434 92 0.8 * * 364 455 400 500
2506A-E15TAG2 * 435 478 92 0.8 * * 400 500 440 550
2806A-E18TAG1A * 522 574 92 0.8 * * 480 600 528 660
2806A-E18TAG2 * 565 609 92 0.8 * * 520 650 560 700
4006-23TAG2A 505 632 695 95 0.8 480 600 600 750 660 825
4006-23TAG3A 540 679 760 94 0.8 512 640 640 800 720 900
4008TWG2 560 710 782 95 0.8 532 665 675 843 743 929
4008TAG 566 715 787 95 0.8 538 672 679 849 748 935
4008TAG1A 606 767 844 95 0.8 576 720 728 911 802 1002
4008TAG2A 681 861 947 95 0.8 647 809 818 1022 900 1125
4012-46TAG0A 842 1053 1158 95 0.8 800 1000 1000 1250 1100 1375
4012-46TWG2A 833 1055 1166 95 0.8 791 989 1002 1253 1108 1385
4012-46TWG3A 909 1149 1263 95 0.8 864 1079 1092 1364 1200 1500
4012-46TAG1A 909 1148 1263 95 0.8 864 1080 1091 1364 1280 1500
4012-46TWG4A  - 1254 1342 96 0.8  - - 1200 1500 1325 1600
4012-46TAG2A 1005 1267 1395 95 0.8 955 1194 1204 1505 1504 1656
4012-46TAG3A 1200 1440 1583 95 0.8 1140 1425 1368 1710 1622 1880
4016-61TRG1 1178 1558 1684 96 0.8 1120 1400 1480 1850 1600 2000
4016TAG1A 1219 1537 1690 96 0.8 1170 1463 1476 1844 1622 2028
4016-61TRG2 1347 1684 1894 96 0.8 1280 1600 1600 2000 1800 2250
4016TAG2A 1362 1715 1886 96 0.8 1307 1634 1646 2058 1811 2263
4016-61TRG3 1500 1875 2083 96 0.8 1440 1800 1800 2250 2000 2500
Gas Power 1500 rev/min (307 kWe to 1000 kWe)
4006-23TRS1† 322  -  - 95.4 1 307 307 - - -
4006-23TRS2† 393  -  - 95.4 1 375 375 - - -
4008-30TRS1† 447  -  - 95 1 425 425 - - -
4008-30TRS2† 526  -  - 95 1 500 500 - - -
4012TESI† 632  -  - 95 1 600 600 - - -
4016-61TRS1† 912  -  - 96 1 875  -  -  -  -  -
4016-61TRS2† 1042  -  - 96 1 1000  -  -  -  -  -
Technical Data
60HZ Net Engine Output Typical Generator Efficiency Typical Power Factor Typical Generating Set Output 1500/1800 rev/min switchable
Model Baseload kWm Prime kWm Standby kWm % Baseload Prime Standby
kWe Kva kWe kVA kWe kVA
1800 rev/min (3.9 kWe to 1504 kWe)
402D-05G * 4.5 5 86 0.8 * * 3.9 4.9 4.3 5.3
403D-07G * 6.6 7.3 86 0.8 * * 5.7 7.1 6.3 7.8
403D-11G * 10.4 11.4 87 0.8 * * 9 11.3 9.9 12.4 ·
403D-15G * 14.4 15.8 88 0.8 * * 12.6 15.8 13.9 17.4 ·
404D-22G * 21.7 23.9 89 0.8 * * 19.3 24.2 21.3 26.6 ·
404D-22TG * 28.8 31.7 89 0.8 * * 25.6 32.1 28.2 35.3
404D-22TAG * 31.5 34.7 89 0.8 * * 28.4 35.5 31.2 39
1103A-33G * 32.2 35.4 87 0.8 * * 27.9 34.9 30.6 38.2 ·
1103A-33TG1 * 48.8 53.9 87 0.8 * * 42.5 53.1 46.9 58.7 ·
1103A-33TG2 * 61.2 66.4 89 0.8 * * 54.5 68.1 60.1 75.1 ·
1104A-44TG1 * 68.6 75.5 89 0.8 * * 60.8 76 66.9 83.6 ·
1104A-44TG2 * 82 90.2 89 0.8 * * 73 91.3 80.3 100.3 ·
1006TG1A * 96.5 106.5 90 0.8 * * 87 109 96 120
1006TG2A * 107 118 90 0.8 * * 96.5 120.5 106 132.5
1006TAG * 134 147 90 0.8 * * 120.5 151 132.5 165.5 ·
1106C-E66TAG2 * 138.4 155.3 92 0.8 * * 127.3 159.2 142.9 178.6 ·
1106C-E66TAG3 * 146.4 163.4 92 0.8 * * 136.1 170.1 152 190 ·
1106C-E66TAG4 * 177.3 196.3 92 0.8 * * 164.9 206.1 182.6 228.2 ·
1106D-E66TAG2 * 136.6 153.6 92 0.8 * * 125 156 140 175
1106D-E66TAG3 * 142.4 159.4 92 0.8 * * 135 169 150 188
1106D-E66TAG4 * 173.7 192.3 92 0.8 * * 160 200 175 219
1306C-E87TAG3 182 201 220 92 0.8 167 209 185 231 202 253 ·
1306C-E87TAG4 194 213 235 92 0.8 178 223 196 245 216 270 ·
2206A-E13TAG5 * 349 381 92 0.8 * * 320 400 350 438 ·
2206A-E13TAG6 * 381 435 92 0.8 * * 350 438 400 500 ·
2506A-E15TAG3 * 446 490 92 0.8 * * 410 513 450 563 ·
2506A-E15TAG4 * 495 543 92 0.8 * * 455 569 500 624 ·
2506C-E15TAG4# - - 597 92 0.8 - - - - 550 687
2806A-E18TAG1A * 543 598 92 0.8 * * 500 625 550 687 ·
2806A-E18TAG3 * 592 652 92 0.8 * * 545 681 600 750 ·
4006-23TAG2A 511 638 702 94 0.8 480 600 600 750 660 825
4008TWG2 534 684 756 95 0.8 507 634 650 812 718 898
4008TAG 564 712 784 95 0.8 536 670 676 846 745 931
4006-23TAG3A 570 715 795 95 0.8 540 675 675 844 750 938
4008TAG1 584 744 821 95 0.8 555 694 707 884 780 975
4008TAG2 659 838 924 95 0.8 626 783 796 995 878 1097
4012-46TWG2A 833 1055 1166 95 0.8 791 989 1002 1253 1108 1385
4012-46TWG3A 909 1149 1263 95 0.8 864 1079 1092 1364 1200 1500
4012-46TAG1A 914 1153 1267 95 0.8 868 1085 1095 1369 1204 1505
4012-46TWG4A - 1254 1342 96 0.8 - - 1200 1500 1280 1600
4012-46TAG2A 1009 1272 1399 95 0.8 959 1199 1208 1510 1329 1669
4012-46TAG3A 1200 1440 1583 95 0.8 1140 1425 1368 1710 1504 1880
1200 rev/min (592 kWe to 1478 kWe)
4008TAG1 491 623 686 95 0.8 466 583 592 740 652 815
4008TAG2 547 693 763 95 0.8 520 650 658 823 725 906
4016TAG 908 1146 1263 96 0.8 872 1091 1100 1375 1212 1515
4016TAG2 1108 1400 1540 96 0.8 1063 1329 1344 1680 1478 1848
Gas Power 1200 rev/min (576 kWe)
4012TESI† 600 - - 96 1 576 576 - - - -

* For switchable engines, please consult with your local Perkins representative.
The engine is available as Electro Unit only.
Notes:
– All ratings are for guidance only, please refer to the specific engine technical data sheet for final powers.
– Perkins conditions of sale apply.
– Electrical output is based on typical generator efficiency and is for guidance only.
– All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is ± 5%.
– Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation.
Please Note: No overload is permitted on 4000 Series.
– Prime Power = Power available at variable load in lieu of main power network (please refer to the engine Technical Data Sheet for engine load factors). An overload of 10% permitted for one hour in every twelve hours of operation.
– Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.
– Emergency Standby Power = Power available in the event of a main power network failure, up to maximum of 200 hours per year which may be run continuously. Load factor may be up to 70% of the Emergency Standby Power rating. No overload is permitted.

Technical Specifications
DIESEL Model Length (A) Height (B) Width (c) Length (D) ElectropaK Dry Weight (kg)
402D-05G
403D-07G 480 528 371 - 71
403D-11G 776 700 449 - 129
403D-15G 820 791 476 - 197
404D-22G 915 840 477 - 242
404D-22TG 988 969 588 - 260
404D-22TAG 1073 997 700 - 300
1103A-33G 1029 951 629 912 412
1103A-33TG1/TG2 1049 951 634 928 420
1104A-44TG1/TG2 1241 951 629 1046 463
1103C-33G2/G3 1045 951 631 928 329
1103C-33TG2/TG3 1048.8 951 634 928 420
1104C-44TG2/TG3 1239 951 614.8 1045.7 401
1104D-44TG1 1238 967 637 - 474
1104C-44TAG1/TAG2 1259 966 721 1121 401
1006TG1A 1559 1124 709 1378 542
1006TG2A 1559 1124 709 1378 586
1006TAG 1685 1065 773 1450 586
1006TAG2 1685 1065 773 1450 586
1104D-E44TG1 1281 940 708 - 483
1104D-E44TAG1/TAG2 1357.7 1090.7 749.6 1067.7 465
1106C-E66TAG2/TAG3 1728.3 1140.4 779.8 1413.8 788
1106C-E66TAG4 1763.2 1140.4 788.3 1421 788
1106D-E66TAG2/TAG3 1728.3 1140.4 779.8 1413.8 788
1106D-E66TAG4 1763.2 1140.4 788.3 1421 788
1306C-E87TAG3/TAG4/TAG5/TAG6 1822 1369 875 1539 895
2206A-E13TAG2/TAG3/TAG5/TAG6 2410 1725 1120 - 1478
2206C-E13TAG2/TAG3 2410 1725 1120 - 1478
2206D-E13TAG2/TAG3 2410 1725 1120 - 1478
2306A-E14TAG2/TAG3 2422 1614 1107 2029 1690
2306C-E14TAG2/TAG3 2657 1718 1120 - 1633
2506A-E15TAG1/TAG2/TAG3/TAG4 2657 1718 1120 - 1633
2506C-E15TAG1/TAG2/TAG3/TAG4 2657 1718 1120 - 1633
2506D-E15TAG1 2657 1718 1120 - 1633
2806A-E18TAG1A/TAG2/TAG3 2545 1807.5 1536 2050 2050
2806C-E18TAG1A/TAG3 2545 1807.5 1536 2050 2050
4006-23TAG2A/TAG3A 3027 1964 1706 2414 2524
4008TAG 3780 2193 1630 3129 3730
4008TAG1/TAG2 3935 2258 1870 3281 4360
4008TAG1A/TAG2A 3852 2067 2046 2921 4270
4008TWG2 2890 1772 1585 2201 3350
4012-46TAG1A/TAG2A/TAG3A 3971 2260 2192 3339 4400
4012-46TWG2A/TWG3A/TWG4A 3714 2255 1978 2930 5283
4016TWG2 4510 3149 2775 3872 8240
4016TAG1A/TAG2A 4460 3239 2775 3827 8010
4016TEG1/TEG2 3450 2115 1410 2812 6000
4016-61TRG/1/2/3 3302 1723 2128 - 5570
Technical Parameters
GAS Model Length (X) Height (Y) Width (Z) Engine Dry Weight
4006-23TRS1/TRS2 2242 1787 1633 1650
4008-30TRS1/TRS2 2658 1782 1633 3350
4012TESI 2650 1860 1895 4680
4016-61TRS1/TRS2 3192 1969 1737 5820

All dimensions are given in mm. All weights are given in kg. Data is approximate only. Perkins reserves the right to change without prior notice.

Emissions Regulations
Perkins can supply engines for power generation applications which satisfy the requirements of TA Luft, 1⁄2 TA Luft regulations andUS EPA and EU off-highway legislation.

Please contact your local Perkins representative for information on specific engine ratings.

A leading Perkins series diesel engine supplier in China, Guangdong RISE Power Equipment Inc. has received ISO9001:2000 certification due to its operation in strict accordance with international standards. In addition to the Perkins series diesel engine, we also provide XinChai series diesel engine, SDEC diesel engine, and a range of generator sets, such as Caterpillar Olympian generator set, Yanmar generator set, Deutz generator set, and John Deere generator set, to name a few. With reliable quality, stable performance, easy operation, safety and durability, our products are highly sought after by a vast number of customers in both domestic and overseas markets. Located in Guangzhou, our company has access to convenient air, sea and land transportation, which helps to lower our transportation cost but save the shipping charges of our customers as well. If you are interested in our diesel engines or generator sets, please feel free to contact us. Staffs at RISE Power look forward to working with you.